Ruud UGRA-12ERAJS Furnace Parts

Shop replacement repair parts for Ruud Furnace model UGRA-12ERAJS/Serial: EL

icons/furnace
Brand:Ruud
Model:UGRA-12ERAJS/Serial: EL
Product:Furnace
79 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
93247 Silicone Sealant
$25.83

2.8 oz Tube of Red Devil High Temp RTV Silicone. Perfect for Gasket replacement. Not for Heat Exchangers.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
70-24033-01 Draft Inducer Motor
$354.25

Induced draft blower motor with gasket, 120 volts. Furnace draft inducer motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
62-24140-04 Control Board
$188.68

Integrated furnace control board. The control board regulates the supply of power to the furnace components. Be sure to check more commonly defective parts before replacing the control board.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
46-101496-01 Transformer
$35.87

Transformer, 120 Volts Primary, 24 Volt Secondary, 40VA

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
70-20602-01K Blower Wheel
$113.69

Blower Wheel, 11 7/8" Diameter x 10 11/16" Wide, 1/2" Bore, CW Rotation

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
47-25350-01K Limit Switch
$11.36

Limit Switch, SPST N/C 190' Open 170' Close

Skill Level (4)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
FP-02 Conversion Kit
$62.40

Natural to Lp Conversion Kit. *Should be installed by a certified Rheem repairperson.

Go

Ruud UGRA-12ERAJS/Serial: EL Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Ruud UGRA-12ERAJS/Serial: EL problems ― and their solutions. Do any of these look familiar?
Furnace not heating
26 possible causes and potential solutions
Furnace not heating
Furnace is noisy or loud
10 possible causes and potential solutions
Furnace is noisy or loud
Furnace starts then stops
13 possible causes and potential solutions
Furnace starts then stops

Frequently Purchased Together For This Model

Flame Sensor
Igniter
Silicone Sealant
Spark Electrode

Maintain peak performance and reliable heating with genuine replacement parts for the Ruud UGRA-12ERAJS Furnace from Repair Clinic. Whether you’re troubleshooting ignition issues, replacing a control board, or performing seasonal maintenance, we carry all the OEM parts needed for fast, effective repairs.

The UGRA-12ERAJS is a high-efficiency gas furnace designed for residential heating systems. If your unit is not igniting, short-cycling, or producing inadequate heat, common components such as flame sensors, igniters, limit switches, or the Ruud furnace control board may need replacement. Use our detailed diagrams and symptom-based repair assistance to find exactly what you need.

We stock a complete inventory of parts for the UGRA-12ERAJS and similar models like the UGTA-12ERAJS, including:

  • Draft inducer motors
  • Ignition modules
  • Flame sensors
  • Blower motors
  • Circuit boards and relays

All parts are 100% genuine Ruud and backed by our 365-day return policy and price match guarantee. You’ll also find helpful installation videos and technical resources to walk you through every step of the repair process.

Why Choose Repair Clinic for UGRA-12ERAJS Parts?

  • OEM Ruud furnace parts in stock
  • Fast shipping with same-day availability
  • 365-day return policy
  • Price match guarantee
  • Expert support and repair resources

Get your Ruud UGRA-12ERAJS furnace running like new. Shop confidently at Repair Clinic today.

Frequently Asked Questions

What are common problems with the Ruud UGRA-12ERAJS?

Frequent issues include failure to ignite, control board malfunction, or blower motor failure. These can usually be resolved by replacing key components such as the igniter, flame sensor, or circuit board.

Where can I find a Ruud UGRA-12ERAJS parts diagram?

You can access exploded-view diagrams for the UGRA-12ERAJS on RepairClinic.com, which show part locations and connections to assist with installation and repair.

Are parts interchangeable between UGRA-12ERAJS and UGTA-12ERAJS models?

Many internal components are compatible, but always verify part numbers before ordering to ensure proper fit and function.

How do I replace the Ruud furnace control board?

First, disconnect power to the unit. Remove the access panel, disconnect all wiring from the old board, mount the new control board, and reconnect wires using the diagram as reference. Repair Clinic offers video tutorials for guidance.

How quickly can I receive Ruud UGRA-12ERAJS replacement parts?

Most in-stock parts ship the same day when you order from Repair Clinic, so you can complete your repair with minimal downtime.