Ruud UGRA-10EZAJS/Serial: EH Furnace Parts & Repair Guide

Shop replacement repair parts for Ruud Furnace model UGRA-10EZAJS/Serial: EH

icons/furnace
Brand:Ruud
Model:UGRA-10EZAJS/Serial: EH
Product:Furnace
76 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
93247 Silicone Sealant
$25.83

2.8 oz Tube of Red Devil High Temp RTV Silicone. Perfect for Gasket replacement. Not for Heat Exchangers.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
70-24033-01 Draft Inducer Motor
$354.25

Induced draft blower motor with gasket, 120 volts. Furnace draft inducer motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
46-101496-01 Transformer
$35.87

Transformer, 120 Volts Primary, 24 Volt Secondary, 40VA

Skill Level (3)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
60-105055-01 Gas Valve Assembly
$242.40

24v 1/2" x 1/2" direct spark ignition standard open Natural Gas

Skill Level (4)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
FP-02 Conversion Kit
$62.40

Natural to Lp Conversion Kit. *Should be installed by a certified Rheem repairperson.

Go

Ruud UGRA-10EZAJS/Serial: EH Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Ruud UGRA-10EZAJS/Serial: EH problems ― and their solutions. Do any of these look familiar?
Furnace not heating
25 possible causes and potential solutions
Furnace not heating
Furnace is noisy or loud
9 possible causes and potential solutions
Furnace is noisy or loud
Furnace starts then stops
11 possible causes and potential solutions
Furnace starts then stops

Frequently Purchased Together For This Model

Flame Sensor
Igniter
Silicone Sealant
Spark Electrode

Maintain and repair your Ruud UGRA-10EZAJS/Serial: EH Furnace with high-quality replacement parts from Repair Clinic. Our extensive inventory ensures you can find the right components for all common furnace repairs, from igniters to control boards.

Search by model number, part category, or specific symptoms to locate the correct parts for your UGRA-10EZAJS/Serial: EH. Use our detailed parts diagrams, troubleshooting tips, and repair guides to make the process easy and efficient.

Common Ruud UGRA-10EZAJS Issues & Solutions

1. Furnace Not Heating

Possible Causes:

  • Faulty Igniter: The igniter may be cracked or malfunctioning.
  • Gas Valve Issues: A defective gas valve may prevent the unit from heating.
  • Clogged Air Filter: A dirty filter can block airflow and impact heating efficiency.

Solution: Replace the igniter, check the gas valve, and clean or replace the air filter.

2. Furnace Making Unusual Noises

Possible Causes:

  • Loose Blower Wheel: The blower wheel may be misaligned or loose.
  • Worn Motor Bearings: Bearings in the fan motor may be failing.
  • Dirty Burners: Carbon buildup can cause rumbling or popping noises.

Solution: Tighten the blower wheel, lubricate or replace motor bearings, and clean the burners.

3. Furnace Not Turning On

Possible Causes:

  • Blown Fuse: A fuse may have blown due to power surges.
  • Thermostat Issues: A faulty thermostat can prevent the unit from starting.
  • Defective Control Board: The furnace may not be receiving signals properly.

Solution: Check and replace fuses, inspect the thermostat, and test the control board.

Essential Ruud UGRA-10EZAJS Replacement Parts

  • Igniter: Ensures the furnace ignites properly.
  • Flame Sensor: Detects burner flames and prevents gas leaks.
  • Blower Motor: Circulates warm air throughout the home.
  • Control Board: Manages various furnace operations.
  • Thermostat: Regulates temperature settings.

Why Buy From Repair Clinic?

  • Genuine Ruud UGRA-10EZAJS/Serial: EH Parts: Guaranteed OEM fit and performance.
  • Same-Day Shipping: Available on in-stock items.
  • DIY Repair Resources: Step-by-step videos and manuals.
  • 365-Day Return Policy: Hassle-free returns.
  • Expert Support: Call 1-800-269-2609 for assistance.

Frequently Asked Questions

1. How do I replace the igniter on my Ruud UGRA-10EZAJS furnace?

  • Turn off power and gas to the furnace.
  • Remove the access panel to locate the igniter.
  • Disconnect the igniter and remove mounting screws.
  • Install the new igniter and reconnect the wires.
  • Restore power and gas, then test the furnace.

2. Why is my Ruud UGRA-10EZAJS furnace not heating properly?

  • Check for a clogged air filter and replace it if necessary.
  • Inspect the gas valve and igniter for defects.
  • Ensure the thermostat is functioning correctly.

3. How often should I clean the furnace burners?

  • Clean the burners at least once a year for optimal performance.
  • More frequent cleaning may be required if you notice soot buildup.