York G8T08012UHA11A Furnace Parts

Shop replacement repair parts for York Furnace model G8T08012UHA11A

icons/furnace
Brand:York
Model:G8T08012UHA11A
Product:Furnace
53 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
S1-03103010000 Control Board
$163.27

Furnace control board. The control board regulates the supply of power to the furnace components.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02532625000 Igniter
$60.68

Furnace hot surface igniter kit. The igniter gets very hot and glows bright orange to light the gas burner. If the igniter is cracked or defective, the furnace won’t heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02420045700 Run Capacitor
$13.07

Genteq Run Capacitor 370 Volt Oval Single 7.5 MFD

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02527773700 Flame Sensor
$37.84

Furnace flame sensor. The flame sensor monitors the burner to detect whether or not a flame is present. If the flame sensor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02435329000 Draft Inducer Motor
$293.91

Draft inducer blower assembly. 60 Hz 1.75 Amps, 3000 RPM.The draft inducer blower draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02440904000 Blower Motor
$324.12

Furnace blower motor. This single-phase motor has the following specifications:

Horsepower: 1/3
Voltage: 115
Full-Load Amperage: 6.2
Hertz: 60
RPM: 1075
Speeds: 4
Rotation: Counterclockwise LE
Frame: 48
Enclosure: Open
Shaft Length: 4”

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02530321700 Flame Rollout Limit Switch
$39.81

Flame rollout limit switch 185 degrees F open, manual reset

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02527747016 Flame Rollout Limit Switch
$27.87

Flame rollout limit switch 320 degrees F open, manual reset

Go

York G8T08012UHA11A Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common York G8T08012UHA11A problems ― and their solutions. Do any of these look familiar?
Furnace not heating
28 possible causes and potential solutions
Furnace not heating
Furnace is noisy or loud
11 possible causes and potential solutions
Furnace is noisy or loud
Furnace starts then stops
17 possible causes and potential solutions
Furnace starts then stops

Frequently Purchased Together For This Model

Control Board
Gas Burner
Igniter
Run Capacitor

Keep your heating system running smoothly with genuine York G8T08012UHA11A replacement parts from Repair Clinic. Whether you’re troubleshooting a heating issue or performing routine maintenance, our inventory includes all the essential components for the G8T08012UHA11A model— from ignitors and flame sensors to control boards, blower motors, and pressure switches.

The York G8T08012UHA11A Furnace is known for its reliability and performance. To maintain peak efficiency and safe operation, it’s important to perform timely repairs using factory-approved parts. Our intuitive parts lookup tool and detailed diagrams make it easy to locate what you need based on part type, function, or common symptoms.

Whether you’re replacing a failed control board or following a G8T08012UHA11A troubleshooting guide to address ignition or airflow issues, our visual resources and repair videos provide the step-by-step instructions to assist any DIYer or professional technician.

Why Choose Repair Clinic for G8T08012UHA11A Parts?

  • Genuine York furnace parts for long-term durability
  • Full access to G8T08012UHA11A manuals and wiring diagrams
  • Same-day shipping on most in-stock items
  • 365-day no-hassle return policy
  • Price match guarantee and expert repair support

Whether you’re addressing ignition failures or routine wear-and-tear, Repair Clinic is your one-stop source for G8T08012UHA11A parts and helpful repair resources. Order today to restore comfort to your home with confidence.

Frequently Asked Questions

What are common issues with the York G8T08012UHA11A furnace?

Typical issues include faulty ignitors, malfunctioning control boards, dirty flame sensors, and blower motor failures. All of these parts are replaceable using genuine York components from Repair Clinic.

How can I troubleshoot a G8T08012UHA11A furnace that won’t start?

Begin by checking the thermostat, circuit breakers, and furnace switch. If these are functional, inspect the ignitor, pressure switch, and control board. Refer to the G8T08012UHA11A manual for step-by-step troubleshooting.

Where can I find the G8T08012UHA11A manual?

You can download the York G8T08012UHA11A manual directly from the product page at Repair Clinic under the “Manuals & Diagrams” section.

How do I replace the flame sensor on my York G8T08012UHA11A?

Turn off power to the furnace, remove the flame sensor mounting screw, disconnect the wire, and install the new sensor. Clean sensors can be reused if they’re in good condition.

Are parts for G8T08012UHA11A interchangeable with other York models?

Some components may be shared with similar York furnace models, but always verify part compatibility with the model number or consult Repair Clinic support before purchasing.