Trane TUH1B060A9361AA Furnace Parts & Repair Help

Shop replacement repair parts for Trane Furnace model TUH1B060A9361AA

icons/furnace
Brand:Trane
Model:TUH1B060A9361AA
Product:Furnace
62 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
SEN01114 Flame Sensor
$22.56

Furnace flame sensor. The flame sensor monitors the burner to detect whether or not a flame is present. If the flame sensor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
SWT01635 Limit Switch
$23.31

Thermal limit switch, open at 180 degrees, close at 150 degrees

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
TRR01729 Transformer
$49.04

Transformer; 115v pri, 24v sec., 60hz, 35va, foot mount

Skill Level (3)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
KIT18110 Control Board
$448.15

Integrated single-stage furnace control board. The control board regulates the supply of power to the furnace components. Be sure to check more commonly defective parts before replacing the control board.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
SWT02124 Flame Rollout Limit Switch
$12.11

Switch; switch-flame rollout, 82 degrees c, 180 deg

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
BLW00864 Draft Inducer Motor
$401.68

Draft inducer motor, one stage with shaded pole motor *Note: All models use this part with the exception of: *UX/DX100A, UX/DX100C, UX/DX1C100, UX1D100, UX/DX120A, UX/DX120C. These select models use item 2458691.

Skill Level (4)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
BAYLPKT210B Conversion Kit
$57.20

Natural Gas To LP Gas Conversion Kit. Kit includes, 7 orifice main burner #56, 1 LP spring conversion kit, 1 propane label, 1 conversion label, 1 conversion responsibility label, 1 installer's guide. *Should be installed by a certified Trane repairperson.

Go

Trane TUH1B060A9361AA Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Trane TUH1B060A9361AA problems ― and their solutions. Do any of these look familiar?
Furnace not heating
23 possible causes and potential solutions
Furnace not heating
Furnace is noisy or loud
9 possible causes and potential solutions
Furnace is noisy or loud
Furnace starts then stops
16 possible causes and potential solutions
Furnace starts then stops

Frequently Purchased Together For This Model

Flame Sensor
Burner Tube
Run Capacitor
Limit Switch

Maintain your Trane TUH1B060A9361AA Furnace with confidence using genuine replacement parts from Repair Clinic. As a key model in Trane’s high-efficiency lineup, the TUH1B060A9361AA offers dependable heating performance—but like any system, it may need occasional repairs and routine maintenance to stay at its best.

Whether you’re troubleshooting ignition issues, replacing a blower motor, or servicing the flame sensor, we provide everything you need. Simply search by model number, part category, or symptoms to find the right Trane TUH1B060A9361AA parts. With access to detailed diagrams, repair guides, and videos, completing your DIY repair is easier than ever.

Common Trane TUH1B060A9361AA Furnace Issues & Fixes

1. Furnace Not Starting

Common Causes:

  • Faulty ignitor or flame sensor
  • Blown fuse or tripped breaker
  • Malfunctioning control board

Solution: Inspect each component and replace any defective parts to restore operation.

2. Weak or No Airflow

Common Causes:

  • Clogged air filter
  • Failing blower motor
  • Blocked return ducts

Solution: Clean or replace the air filter, inspect the motor, and clear obstructions.

3. Furnace Shuts Off Too Soon

Common Causes:

  • Faulty limit switch
  • Overheating due to restricted airflow
  • Short cycling from a bad thermostat

Solution: Replace the limit switch, check for airflow restrictions, and verify thermostat calibration.

Top Replacement Parts for Trane TUH1B060A9361AA

  • Ignitor: Lights the burner for combustion
  • Flame Sensor: Confirms the presence of a burner flame
  • Blower Motor: Circulates heated air through the home
  • Limit Switch: Prevents overheating by shutting down burners
  • Control Board: Coordinates ignition, fan, and safety controls

FAQs

1. What is the efficiency rating of the TUH1B060A9361AA?

  • This model is part of Trane’s high-efficiency furnace line and features an AFUE rating around 95%.

2. How do I troubleshoot a Trane TUH1B060A9361AA not heating?

  • Check for a dirty flame sensor, faulty ignitor, or tripped limit switch. Replace any failed parts for proper heating.

3. How often should I service my TUH1B060A9361AA?

  • Annual maintenance is recommended, including filter changes, flame sensor cleaning, and a system diagnostic check.