DescriptionThis video provides step-by-step repair instructions for replacing the control panel on a Kitchenaid Gas Convection Range (model #KSGB900ESS01). The most common reason for replacing the panel is if it is damaged.
This control panel replacement video is applicable to the following brands:
Whirlpool, Kitchenaid
Don't forget to like and comment on this video and subscribe to our channel!
Step-By-Step Instructions1
Convection gas range - ksgb900ess1
2
Kitchenaid convection gas range - Control Panel Replacement
3
You will need a phillips-head screwdriver to complete this repair.
5
Unplug The Power Cord Or Shut Off The Power Supply.
7
Shut Off The Gas Supply As Well.
9
Use A Phillips-head Screwdriver To Unthread The Screws Securing The Control Panel?s Lower Cover.
12
Pull Off The Five Control Knobs.
13
Next, Unthread The Two Screws Securing The Control Panel To The Frame.
14
Detach The Control Panel, Then Disconnect The Display Board Wire Connecter And The Touch-pad Ribbon Connecter To Fully Release The Panel.
15
Now Unthread The Five Screws Securing The Display Board Mounting Bracket And Protective Covers.
16
Remove The Screws To Detach The Two End Caps.
17
You?re Now Ready To Prepare The New Control Panel For Installation.
18
Align The Two End Caps, And Secure Them With The Screws.
19
Position The Display Board And Mounting Bracket, Align The Protective Covers, Then Thread And Tighten The Screws.
20
Returning To The Range, Connect The Wire Connecter To The Display Board, And The Ribbon Connecter To The Touch-pad.
21
Align The New Control Panel On The Front Brackets.
22
Secure It With The Screws.
23
Replace The Lower Cover, Then Thread The Screws To Secure.
24
You Will Now Need To Install New Control Knob Bezels On The Control Panel.
25
You Can Place The Bezel In An Alignment Tool So The Locating Tab Aligns With The Red Marking On The Bezel.
26
This Will Help You To Position The Bezel So It Is Centered Over The Valve Stem.
27
With The Five Bezels Secured, Replace The Control Knobs - Note That The Power Burner Control Knob Should Be Placed On The Second Stem From The Left.
28
Turn The Gas Supply Back On.
29
Plug The Power Cord Back In Or Restore The Power Supply.