24v Contactor Relay 2 Pole 30 Amp
Grid is 1 inch square
SFCTR2P30A24VSA Trane Contactor
SFCTR2P30A24VSA Trane Contactor
Manufacturer Part

SFCTR2P30A24VSA Trane Contactor

Genuine OEM Part # SFCTR2P30A24VSAAlternative Part Number(s)
Manufacturer Part
24v Contactor Relay 2 Pole 30 Amp
Grid is 1 inch square
SFCTR2P30A24VSA Trane Contactor
SFCTR2P30A24VSA Trane Contactor
$38.04
Loading stock status
Loading stock status
Does this part fit my product?
Find your model number or log in to select it from your saved machines.
24v Contactor Relay 2 Pole 30 Amp
Loading stock status
$38.04
start a live chat with Repair Clinic customer support

This part SFCTR2P30A24VSA is compatible with:

Product Type:
Air Handler, Central Air Conditioner, Heat Pump, Packaged Unit/RTU

Related Articles & Videos

04:24
How This Part Works
Central Air Condensing Unit Contactor - How it Works & Installation Tips
03:12
Troubleshooting
Central Air Conditioner Not Cooling — Central Air Conditioner Troubleshooting
02:01
Troubleshooting
Central Air Conditioner Fan Motor Not Running — Central Air Conditioner Troubleshooting
01:47
Troubleshooting
Central Air Conditioner Is Noisy — Central Air Conditioner Troubleshooting
02:21
Troubleshooting
Central Air Conditioner Not Running — Central Air Conditioner Troubleshooting
Frequently Bought with Contactor
WP694089 Blower Wheel

Contactor Customer Reviews

Common Problems Fixed by the Contactor

Based on customer reports and repair data, this part commonly fixes these issues:

Very Likely

Central air conditioner not cooling properly

Likely

Heat pump compressor won't run

Likely

Heat pump won't turn off

Likely

Air handler not cooling properly

Likely

Heat pump not cooling

Likely

Heat pump not heating

Likely

Heat pump won't turn on

Likely

Central air conditioner compressor won't run

Likely

Air handler not heating

Possible

Central air conditioner won't turn off

Possible

Central air conditioner is noisy or loud

Possible

Heat pump is noisy or loud

Possible

Central Air Conditioner Condensing unit does not run

About the Contactor

The furnace control board sends a low voltage signal to the contactor. When the contactor receives the signal from the control board, it closes the circuit, sending voltage to the condensing unit components. If the contactor is defective, it will not provide voltage to the condensing unit. To determine if the contactor is at fault, use a multimeter to test the contactor for continuity. If the contactor does not have continuity, replace it.

Popular models

Alternative Part Number(s)

Replaces Part Number CTR01038
Replaces Part Number CTR01146
Replaces Part Number CTR02573