General Purpose Relay.  DPDT PILOT 3amp, POWER 12 amp.
Grid is 1 inch square
Trane Contactor RLY02463
Trane Contactor RLY02463
Trane Contactor RLY02463
Manufacturer Part

Trane Contactor RLY02463

Genuine OEM Part # RLY02463RC Item # 2573941Alternative Part Number(s)
Manufacturer Part
General Purpose Relay.  DPDT PILOT 3amp, POWER 12 amp.
Grid is 1 inch square
Trane Contactor RLY02463
Trane Contactor RLY02463
Trane Contactor RLY02463
$64.53
Loading stock status
Loading stock status
Does this part fit my product?
Find your model number or log in to select it from your saved machines.
General Purpose Relay. DPDT PILOT 3amp, POWER 12 amp.
Loading stock status
$64.53
start a live chat with Repair Clinic customer support

This part RLY02463 is compatible with:

Product Type:
Central Air Conditioner
Brands:
Trane

Related Articles & Videos

04:24
How This Part Works
Central Air Condensing Unit Contactor - How it Works & Installation Tips
03:12
Troubleshooting
Central Air Conditioner Not Cooling — Central Air Conditioner Troubleshooting
02:01
Troubleshooting
Central Air Conditioner Fan Motor Not Running — Central Air Conditioner Troubleshooting
01:47
Troubleshooting
Central Air Conditioner Is Noisy — Central Air Conditioner Troubleshooting
02:21
Troubleshooting
Central Air Conditioner Not Running — Central Air Conditioner Troubleshooting
Frequently Bought with Contactor
P291-4554RS Dual Run Capacitor
297286803 Run Capacitor
LH680534 Flame Sensor
S1-03103010000 Control Board

Contactor Customer Reviews

Common Problems Fixed by the Contactor

Based on customer reports and repair data, this part commonly fixes these issues:

Very Likely

Central air conditioner not cooling properly

Likely

Heat pump compressor won't run

Likely

Heat pump won't turn off

Likely

Air handler not cooling properly

Likely

Heat pump not cooling

Likely

Heat pump not heating

Likely

Heat pump won't turn on

Likely

Central air conditioner compressor won't run

Likely

Air handler not heating

Possible

Central air conditioner won't turn off

Possible

Central air conditioner is noisy or loud

Possible

Heat pump is noisy or loud

Possible

Central Air Conditioner Condensing unit does not run

About the Contactor

The furnace control board sends a low voltage signal to the contactor. When the contactor receives the signal from the control board, it closes the circuit, sending voltage to the condensing unit components. If the contactor is defective, it will not provide voltage to the condensing unit. To determine if the contactor is at fault, use a multimeter to test the contactor for continuity. If the contactor does not have continuity, replace it.

Popular models

Repair Help by Brands and Product Type

Alternative Part Number(s)

Replaces Part Number RLY00972
Replaces Part Number RLY01384
Replaces Part Number RLY2463