Lennox contactor for 1.5-3 ton spst 25fla/35res
Grid is 1 inch square
  Contactor 10F73
  Contactor 10F73
  Contactor 10F73
  Contactor 10F73
  Contactor 10F73
Manufacturer Part

Contactor 10F73

Genuine OEM Part # 10F73RC Item # 3289606Alternative Part Number(s)
Manufacturer Part
Lennox contactor for 1.5-3 ton spst 25fla/35res
Grid is 1 inch square
  Contactor 10F73
  Contactor 10F73
  Contactor 10F73
  Contactor 10F73
  Contactor 10F73
$37.37
Loading stock status
Estimated DIY Savings: $217.11
Loading stock status
Does this part fit my product?
Find your model number or log in to select it from your saved machines.
Lennox contactor for 1.5-3 ton spst 25fla/35res
Loading stock status
$37.37
start a live chat with Repair Clinic customer support

This part 10F73 is compatible with:

Product Type:
Air Conditioner, Central Air Conditioner
Brands:
GE, Lennox

Related Articles & Videos

03:09
Part Replacement
Lennox Condensing Unit Contactor Replacement #10F73
04:24
How This Part Works
Central Air Condensing Unit Contactor - How it Works & Installation Tips
03:12
Troubleshooting
Central Air Conditioner Not Cooling — Central Air Conditioner Troubleshooting
02:01
Troubleshooting
Air Conditioner Loud or Noisy — Air Conditioner Troubleshooting
03:57
Troubleshooting
Air Conditioner Fan Not Working — Air Conditioner Troubleshooting
Frequently Bought with Contactor
P291-4554RS Dual Run Capacitor
W10311524 Air Filter
LA660003 Fan Blade
WP694089 Blower Wheel

Contactor Customer Reviews

Common Problems Fixed by the Contactor

Based on customer reports and repair data, this part commonly fixes these issues:

Very Likely

Central air conditioner not cooling properly

Likely

Heat pump compressor won't run

Likely

Heat pump won't turn off

Likely

Air handler not cooling properly

Likely

Heat pump not cooling

Likely

Heat pump not heating

Likely

Heat pump won't turn on

Likely

Central air conditioner compressor won't run

Likely

Air handler not heating

Possible

Central air conditioner won't turn off

Possible

Central air conditioner is noisy or loud

Possible

Heat pump is noisy or loud

Possible

Central Air Conditioner Condensing unit does not run

About the Contactor

The furnace control board sends a low voltage signal to the contactor. When the contactor receives the signal from the control board, it closes the circuit, sending voltage to the condensing unit components. If the contactor is defective, it will not provide voltage to the condensing unit. To determine if the contactor is at fault, use a multimeter to test the contactor for continuity. If the contactor does not have continuity, replace it.

Alternative Part Number(s)

Replaces Part Number 95M55
Replaces Part Number 52M48
Replaces Part Number 65C69
Replaces Part Number 72L10
Replaces Part Number 100438-01
Replaces Part Number 20F7201
Replaces Part Number 46F4001
Replaces Part Number 52M4801
Replaces Part Number 65C6901
Replaces Part Number 72L1001
Replaces Part Number 84K7301
Replaces Part Number 20F72
Replaces Part Number 24F77
Replaces Part Number 46F40
Replaces Part Number 65C36
Replaces Part Number 84K73
Replaces Part Number 100438-04